Transmission & Teleprotection_Signicent

Transmission and Teleprotection Report: How does innovation bring transition in the market?

The objective of this Transmission and Teleprotection Report is to explore the technological intelligence in the domain of transmission and teleprotection systems for high voltage electrical networks.


Electric power transmission is a large-scale transfer of electrical energy from a generating site, such as a power plant, to an electrical substation. Teleprotection is recognized as the greatest technology to convert from time-division multiplexing (TDM) to packet-based networks. Teleprotection is a crucial technology for safeguarding the integrity of high voltage grids. It is a protection system that keeps an eye on the grid’s condition. It can eliminate both external and internal faults and prevent damage to critical parts of the power grid.

There have been significant improvements in the transmission and teleprotection systems but some of the problems pertaining to this domain are highlighted further.

Problems Associated

  • External and internal faults in transmission lines
  • Over-currents or short-circuiting
  • Over-voltages resulting in equipment damage
  • Damage to operators
  • Critical transmission delay between transmitter and receiver
  • Malfunction/damage of a power system due to increased transmission delay

Innovative Solutions

This section of the transmission and teleprotection report demonstrates Signicent’s analysis to determine the novel innovations overcoming the various problems associated with high voltage electrical networks.

THANOS: Teleprotection Holistic Application for ONOS Controller

THANOS was developed to deploy, configure, and manage substation automation and control communication systems in accordance with the IEC 61850 standard. It is an implementation of the ARES conceptual framework for teleprotection situations. Real teleprotection communication infrastructure can be quickly and cost-effectively set up and managed using THANOS.

THANOS is built on top of the ONOS SDN controller. It is a reliable controller platform based on the widely used OpenFlow protocol that supports distributed controllers for automatic failure response. When a network link fails or there are no backup paths available, THANOS monitors the link and generates UI alerts. Additionally, it supports the temporal limits of teleprotection messages and prioritizes vital traffic using OpenFlow switch queues.

5G for Smart Grid Teleprotection

The main focus of 5G is to couple smart grid services with different technologies like uRLLC, mMTC, and eMBB. The success of 5G use cases in teleprotection depends on the cost to maintain the uRLLC feature. In order to achieve the success of 5G cases, it will necessarily require considering the security, guaranteed QoS, redundancy, and also adequate backup power. The main obstacles that are preventing 5G from being a trusted and affordable alternative for teleprotection are:

  • 5G synchronization
  • Lack of 5G rural coverage
  • Lengthy delays due to the number of hops
  • Lack of backup power

Many crucial applications can be supported and facilitated by the usage of URLLC (Ultra-Reliable Low-Latency Communication) in emerging smart grid applications. Some of them are listed below:

  • Protection automation
  • Interlocking
  • Digital substations
  • Remote control for HV and Virtual/Augmented Reality (VR/AR) in a primary substation environment

Each year Signicent provides consultancy to hundreds of organizations to help transform their innovations to value.


Fast-Failover Path Recovery Algorithm for Software-Defined Networks

The suggested algorithm meets the strict quality of service standards, particularly end-to-end delay, for teleprotection and control power systems. This algorithm works to configure industrial switches with vanilla OpenFlow for electrical substations in order to ensure delay limitations for power-system protection mechanisms using unicast flows. The suggested approach delivers all packets that satisfy the teleprotection constraint requirements without any packet loss during link failures.

IEC 61850 teleprotection IED: configured for inter-substation communication

An engineering tool is designed for inter-substation teleprotection. In accordance with IEC 61850, the teleprotection commands are transmitted through a first and second substation communication network. During transmission, the connected communication network of IED with the teleprotection commands gives a link specification for the teleprotection link. The teleprotection link transmitting any command over it will offer an application scheme such as blocking, permissive, and direct tripping generated, or by an IED Capability Description (ICD) generation module.

Market Analysis

An effective market study can assist in gaining important insights into economic changes, ongoing market trends, demography, and the characteristics of customers’ expenditures.  Market analysis provides the firm with all the essential information and different market trends which can ultimately help in making wise business decisions.

The global teleprotection in the high voltage systems market is expected to reach the US $68.09 billion by 2026 from US $19.94 billion in 2021 at a CAGR of 27.8%.

Leading Players

Under this section of the transmission and teleprotection report, the major key players working in the domain are listed below.

Leading companies working in transmission and teleprotection domain.

Recent Report

Related Posts

Virtual Protection Relay by Signicent
Virtual Protection Relay Report: What Market Trends Are Expected?

The objective of the Virtual Protection Relay report is to conduct an investigational...

Non - Fungible Tokens Signicent
Non-Fungible Token Report: How Blockchain is Mobilizing Market?

The non-fungible token report will shed light on a technology intelligence study on...